VizieR

CfA VizieR . ADAC VizieR . Cambridge (UK) VizieR . IUCAA VizieR . INASAN VizieR .

VizieR

  
J/A+A/701/A144
  Stacked X-ray spectra of eROSITA AGN (Chen+, 2025)
Post annotation
img(gal)
1.J/A+A/701/A144/ecftableEnergy conversion factor table (72 rows)

 
Query by Constraints constraints help applied on Columns (Output Order: + - )
ShowSortColumn  Constraint Explain   (UCD)
  recno  Record number assigned by the VizieR team. Should Not be used for identification. (meta.record)
  e_logMBH [Msun] Lower edge of log BH mass bin (stat.error;stat.min)
  E_logMBH [Msun] Upper edge of log BH mass bi (stat.error;stat.max)
  e_logEdd   [] Lower edge of log Eddington ratio bin (stat.error;stat.min)
  E_logEdd   [] Upper edge of log Eddington ratio bin (stat.error;stat.max)
  e_z  Lower edge of redshift (stat.error;stat.min)
  E_z  Upper edge of redshift (stat.error;stat.max)
  CRband (char) Observed-frame energy range (keV) from which to calculate count rate (CountrateBand) (meta.code)
  gamma  Photon index in "CRband" band (gamma) (spect.index)
  e_gamma  Lower error of gamma (16th-50th quantile) (e_gamma) (stat.error;stat.min)
  E_gamma  Upper error of gamma (50th-84th quantile) (E_gamma) (stat.error;stat.max)

ALL cols
    
 (i)indexed column
  logecfEro mW/m2 Log10 energy conversion factor from flux (erg/cm2/s) to count rate (logecfEro) (Note 1)   (arith.factor)
  e_logecfEro mW/m2 Lower error of logecfEro (16th-50th quantile) (e_logecfEro) (stat.error;stat.min)
  E_logecfEro mW/m2 Upper error of logecfEro (50th-84th quantile) (E_logecfEro) (stat.error;stat.max)
  FP00  Rest-frame 0.1-10.0 keV flux to observed-frame "CRband" band flux ratio (FP00) (phot.flux;em.X-ray)
  e_FP00  Lower error of FP00 (16th-50th quantile) (e_FP00) (stat.error;stat.min)
  E_FP00  Upper error of FP00 (50th-84th quantile) (E_FP00) (stat.error;stat.max)
  FP01  Rest-frame 0.2-0.5 keV flux to observed-frame "CRband" band flux ratio (FP01) (phot.flux;em.X-ray)
  e_FP01  Lower error of FP01 (16th-50th quantile) (e_FP01) (stat.error;stat.min)
  E_FP01  Upper error of FP01 (50th-84th quantile) (E_FP01) (stat.error;stat.max)
  FP02  Rest-frame 0.2-2.0 keV flux to observed-frame "CRband" band flux ratio (FP02) (phot.flux;em.X-ray)
  e_FP02  Lower error of FP02 (16th-50th quantile) (e_FP02) (stat.error;stat.min)
  E_FP02  Upper error of FP02 (50th-84th quantile) (E_FP02) (stat.error;stat.max)
  FP03  Rest-frame 0.2-2.3 keV flux to observed-frame "CRband" band flux ratio (FP03) (phot.flux;em.X-ray)

ALL cols
    
 (i)indexed column
  e_FP03  Lower error of FP02 (16th-50th quantile) (e_FP03) (stat.error;stat.min)
  E_FP03  Upper error of FP02 (50th-84th quantile) (E_FP03) (stat.error;stat.max)
  FP04  Rest-frame 0.2-12.0 keV flux to observed-frame "CRband" band flux ratio (FP04) (phot.flux;em.X-ray)
  e_FP04  Lower error of FP02 (16th-50th quantile) (e_FP04) (stat.error;stat.min)
  E_FP04  Upper error of FP02 (50th-84th quantile) (E_FP04) (stat.error;stat.max)
  FP05  Rest-frame 0.5-1.0 keV flux to observed-frame "CRband" band flux ratio (FP05) (phot.flux;em.X-ray)
  e_FP05  Lower error of FP02 (16th-50th quantile) (e_FP05) (stat.error;stat.min)
  E_FP05  Upper error of FP02 (50th-84th quantile) (E_FP05) (stat.error;stat.max)
  FP06  Rest-frame 0.5-1.2 keV flux to observed-frame "CRband" band flux ratio (FP06) (phot.flux;em.X-ray)
  e_FP06  Lower error of FP02 (16th-50th quantile) (e_FP06) (stat.error;stat.min)
  E_FP06  Upper error of FP02 (50th-84th quantile) (E_FP06) (stat.error;stat.max)
  FP07  Rest-frame 0.5-2.0 keV flux to observed-frame "CRband" band flux ratio (FP07) (phot.flux;em.X-ray)
  e_FP07  Lower error of FP02 (16th-50th quantile) (e_FP07) (stat.error;stat.min)

ALL cols
    
 (i)indexed column
  E_FP07  Upper error of FP02 (50th-84th quantile) (E_FP07) (stat.error;stat.max)
  FP08  Rest-frame 0.5-4.5 keV flux to observed-frame "CRband" band flux ratio (FP08) (phot.flux;em.X-ray)
  e_FP08  Lower error of FP02 (16th-50th quantile) (e_FP08) (stat.error;stat.min)
  E_FP08  Upper error of FP02 (50th-84th quantile) (E_FP08) (stat.error;stat.max)
  FP09  Rest-frame 0.5-7.0 keV flux to observed-frame "CRband" band flux ratio (FP09) (phot.flux;em.X-ray)
  e_FP09  Lower error of FP02 (16th-50th quantile) (e_FP09) (stat.error;stat.min)
  E_FP09  Upper error of FP02 (50th-84th quantile) (E_FP09) (stat.error;stat.max)
  FP10  Rest-frame 1.0 keV monochromatic flux to observed-frame "CRband" band flux ratio (FP10) (phot.flux;em.X-ray)
  e_FP10  Lower error of FP02 (16th-50th quantile) (e_FP10) (stat.error;stat.min)
  E_FP10  Upper error of FP02 (50th-84th quantile) (E_FP10) (stat.error;stat.max)
  FP11  Rest-frame 1.0 keV monochromatic flux (soft excess removed) to observed-frame "CRband" band flux ratio (FP11) (phot.flux;em.X-ray)
  E_FP11  Lower error of FP02 (16th-50th quantile) (e_FP11) (stat.error;stat.max)
  e_FP11  Upper error of FP02 (50th-84th quantile) (E_FP11) (stat.error;stat.min)

ALL cols
    
 (i)indexed column
  FP12  Rest-frame 1.0-2.0 keV flux to observed-frame "CRband" band flux ratio (FP12) (phot.flux;em.X-ray)
  e_FP12  Lower error of FP02 (16th-50th quantile) (e_FP12) (stat.error;stat.min)
  E_FP12  Upper error of FP02 (50th-84th quantile) (E_FP12) (stat.error;stat.max)
  FP13  Rest-frame 1.2-2.0 keV flux to observed-frame "CRband" band flux ratio (FP13) (phot.flux;em.X-ray)
  E_FP13  Lower error of FP02 (16th-50th quantile) (e_FP13) (stat.error;stat.max)
  e_FP13  Upper error of FP02 (50th-84th quantile) (E_FP13) (stat.error;stat.min)
  FP14  Rest-frame 2.0-4.5 keV flux to observed-frame "CRband" band flux ratio (FP14) (phot.flux;em.X-ray)
  e_FP14  Lower error of FP02 (16th-50th quantile) (e_FP14) (stat.error;stat.min)
  E_FP14  Upper error of FP02 (50th-84th quantile) (E_FP14) (stat.error;stat.max)
  FP15  Rest-frame 2.0-5.0 keV flux to observed-frame "CRband" band flux ratio (FP15) (phot.flux;em.X-ray)
  e_FP15  Lower error of FP02 (16th-50th quantile) (e_FP15) (stat.error;stat.min)
  E_FP15  Upper error of FP02 (50th-84th quantile) (E_FP15) (stat.error;stat.max)
  FP16  Rest-frame 2.0-7.0 keV flux to observed-frame "CRband" band flux ratio (FP16) (phot.flux;em.X-ray)

ALL cols
    
 (i)indexed column
  e_FP16  Lower error of FP02 (16th-50th quantile) (e_FP16) (stat.error;stat.min)
  E_FP16  Upper error of FP02 (50th-84th quantile) (E_FP16) (stat.error;stat.max)
  FP17  Rest-frame 2.0-10.0 keV flux to observed-frame "CRband" band flux ratio (FP17) (phot.flux;em.X-ray)
  e_FP17  Lower error of FP02 (16th-50th quantile) (e_FP17) (stat.error;stat.min)
  E_FP17  Upper error of FP02 (50th-84th quantile) (E_FP17) (stat.error;stat.max)
  FP18  Rest-frame 2.0-12.0 keV flux to observed-frame "CRband" band flux ratio (FP18) (phot.flux;em.X-ray)
  e_FP18  Lower error of FP02 (16th-50th quantile) (e_FP18) (stat.error;stat.min)
  E_FP18  Upper error of FP02 (50th-84th quantile) (E_FP18) (stat.error;stat.max)
  FP19  Rest-frame 4.0-10.0 keV flux to observed-frame "CRband" band flux ratio (FP19) (phot.flux;em.X-ray)
  e_FP19  Lower error of FP02 (16th-50th quantile) (e_FP19) (stat.error;stat.min)
  E_FP19  Upper error of FP02 (50th-84th quantile) (E_FP19) (stat.error;stat.max)
  FP20  Rest-frame 4.5-12.0 keV flux to observed-frame "CRband" band flux ratio (FP20) (phot.flux;em.X-ray)
  e_FP20  Lower error of FP02 (16th-50th quantile) (e_FP20) (stat.error;stat.min)

ALL cols
    
 (i)indexed column
  E_FP20  Upper error of FP02 (50th-84th quantile) (E_FP20) (stat.error;stat.max)
  FP21  Rest-frame 5.0-8.0 keV flux to observed-frame "CRband" band flux ratio (FP21) (phot.flux;em.X-ray)
  e_FP21  Lower error of FP02 (16th-50th quantile) (e_FP21) (stat.error;stat.min)
  E_FP21  Upper error of FP02 (50th-84th quantile) (E_FP21) (stat.error;stat.max)
  FP22  Rest-frame 5.1-6.1 keV flux to observed-frame "CRband" band flux ratio (FP22) (phot.flux;em.X-ray)
  e_FP22  Lower error of FP02 (16th-50th quantile) (e_FP22) (stat.error;stat.min)
  E_FP22  Upper error of FP02 (50th-84th quantile) (E_FP22) (stat.error;stat.max)
  FP23  Rest-frame 6.2-7.1 keV flux to observed-frame "CRband" band flux ratio (FP23) (phot.flux;em.X-ray)
  e_FP23  Lower error of FP02 (16th-50th quantile) (e_FP23) (stat.error;stat.min)
  E_FP23  Upper error of FP02 (50th-84th quantile) (E_FP23) (stat.error;stat.max)
  FP24  Rest-frame 7.2-8.2 keV flux to observed-frame "CRband" band flux ratio (FP24) (phot.flux;em.X-ray)
  e_FP24  Lower error of FP02 (16th-50th quantile) (e_FP24) (stat.error;stat.min)
  E_FP24  Upper error of FP02 (50th-84th quantile) (E_FP24) (stat.error;stat.max)

ALL cols
    
 (i)indexed column
Adapt form
Display your selection only Reset to default columns
usage  Display UCD1+    UCD1  
elapse time 0