Access to Astronomical Catalogues

← Click to display the menu
J/MNRAS/390/59      X-ray sources in NGC 5775                (Li+, 2008)

Chandra observation of the edge-on spiral NGC 5775: probing the hot galactic disc/halo connection. Li J.-T., Li Z., Wang Q.D., Irwin J.A., Rossa J. <Mon. Not. R. Astron. Soc., 390, 59-70 (2008)> =2008MNRAS.390...59L
ADC_Keywords: X-ray sources Keywords: galaxies: general - galaxies: individual: NGC 5775 - galaxies: spiral - X-rays: general Abstract: We study the edge-on galaxy NGC 5775, utilizing a 58.2ks Chandra ACIS-S observation together with complementary Hubble Space Telescope (HST) ACS, Spitzer IRAC and other multi-wavelength data sets. This edge-on galaxy, with its disc-wide active star formation, is particularly well suited for studying the disc/halo interaction on subgalactic scales. We detect 27 discrete X-ray sources within the D25 region of the galaxy, including an ultra-luminous source with a 0.3-7keV luminosity of ∼7x1040erg/s. Description: The archival Chandra observation of NGC 5775 (Obs. ID. 2940) was taken on April 5, 2002, with a total effective exposure of 58.2ks. File Summary:
FileName Lrecl Records Explanations
ReadMe 80 . This file table2.dat 68 99 Chandra Source List
See also: J/ApJ/574/258 : X-ray-emitting young stars in Orion nebula (Feigelson+, 2002) Byte-by-byte Description of file: table2.dat
Bytes Format Units Label Explanations
1- 2 I2 --- [LLW2008] Source sequential number 4- 22 A19 --- CXOU CXOU Name (JHHMMSS.ss+DDMMSS.s) 24- 26 F3.1 arcsec e_Pos Position uncertainty (1) 28- 32 F5.2 ct/ks CR On-axis source broad-band count rate 34- 37 F4.2 ct/ks e_CR rms uncertainty on CR 39- 43 F5.2 --- HR ? Hardness ratio, HR=(H-S2)/(H+S2) (2) 45- 48 F4.2 --- e_HR ? rms uncertainty on HR 51- 55 F5.2 --- HR1 ? Hardness ratio 1, HR1=(S2-S1)/S (2) 57- 60 F4.2 --- e_HR1 ? rms uncertainty on HR1 62- 68 A7 --- Det [BSH, ] Bands in which the source is detected (3)
Note (1): Position uncertainty calculated from the maximum likelihood centroiding and an approximate off-axis angle (r) dependent systematic error 0.2+1.4(r/8arcmin)2arcsec (an approximation to fig. 4 of Feigelson et al., 2002, Cat. J/ApJ/574/258), which are added in quadrature. Note (2): Listed only for values with uncertainties less than 0.2. Bands are S1=0.3-0.7keV, S2=0.7-1.5keV, H1=1.5-3keV and H2=3-7keV. Note (3): The label 'B' (broad-band), 'S' (soft) or 'H' (hard) mark the band in which a source is detected with the most accurate position that is adopted in Column CXOU
History: From electronic version of the journal
(End) Patricia Vannier [CDS] 18-Oct-2008
The document above follows the rules of the Standard Description for Astronomical Catalogues.From this documentation it is possible to generate f77 program to load files into arrays or line by line

catalogue service

© UDS/CNRS

Contact